Building & Landlord Data for 815 Gravesend Neck Rd, Brooklyn, NY 11223

High Risk Building

Apartments at 815 Gravesend Neck Rd, Brooklyn are more likely to have maintenance issues than 97% of NYC rentals.

  • 8% chance of no major maintenance issues next year
  • 45% chance of one major maintenance issue next year
  • 47% chance of multiple major maintenance issues next year

Building Information

Total Apartments 100
Registered Rent Stabilized Apartments (2017 tax bills) None
Building Listed as Rent Stabilized by the RGB True
Building Class Elevator Apt; Semi-Fireproof Without Stores
Year Built 1962
Zoning Code R4
Area 108000 sq ft
Stories 6
Tax Abatements None

Landlord Details

Role Name Address
Corporate Owner Treger Management Llc 222 Lenox Rd, Brooklyn
Head Officer Marc Barron 222 Lenox Rd, Brooklyn
Agent Marc Barron 222 Lenox Rd, Brooklyn

Building Data Preview

Only the first 10 items in each category are shown.

Housing Protection Department Code Violations (10 found)

Date Filed Date Abated Item Category Status
06/21/20 Section 27-2043.1 Hmc Install The Missing Or Repair/replace The Defective Window Guard(s) In Accordance With The Specifications Of The New York City Health Code Section 24 Rcny Chapter 12. Wg To Install = 0; Wg To Replace = 0; Wg To Repair = 3; In The Entire Apartment Located At Apt 6h, 6th Story, 2nd Apartment From North At East C Nov Sent Out
08/08/14 06/09/16 Section 27-2005 Hmc:trace And Repair The Source And Abate The Nuisance Consisting Of Mold ... At Ceiling And East Wall. Approx. = 8 Square Feet In The 3rd Room From North Located At Apt 3j, 3rd Story, 3rd Apartment From North At East B Violation Closed
08/08/14 06/09/16 Section 27-2026, 2027 Hmc: Properly Repair The Source And Abate The Evidence Of A Water Leak At Ceiling And East Wall In The 3rd Room From North Located At Apt 3j, 3rd Story, 3rd Apartment From North At East B Violation Closed
08/08/14 06/09/16 Section 27-2005 Adm Code Repair The Broken Or Defective Plastered Surfaces And Paint In A Uniform Color Ceiling And East Wall In The 3rd Room From North Located At Apt 3j, 3rd Story, 3rd Apartment From North At East B Violation Closed
08/08/14 Section 27-2005 Adm Code Repair The Broken Or Defective Plastered Surfaces And Paint In A Uniform Color Ceiling And East Wall In The 1st Room From East Located At Apt 3j, 3rd Story, 3rd Apartment From North At East B Not Complied With
08/08/14 06/09/16 Section 27-2026, 2027 Hmc: Properly Repair The Source And Abate The Evidence Of A Water Leak At Ceiling And East Wall In The 1st Room From East Located At Apt 3j, 3rd Story, 3rd Apartment From North At East B Violation Closed
06/20/14 10/22/14 Section 27-2026, 2027 Hmc: Properly Repair The Source And Abate The Evidence Of A Water Leak At Ceiling In The 1st Room From East At North Located At Apt 3r, 3rd Story, 1st Apartment From North At East , 1st Section From West At North B Violation Dismissed
06/20/14 10/22/14 Section 27-2005 Adm Code Repair The Broken Or Defective Plastered Surfaces And Paint In A Uniform Color All Walls And Ceiling In The 1st Room From East At North Located At Apt 3r, 3rd Story, 1st Apartment From North At East , 1st Section From West At North B Violation Dismissed
06/20/14 10/22/14 Section 27-2046.1, 2046.2 Hmc: Provide An Approved And Operational Carbon Monoxide Detecting Device, Installed In Accordance With Applicable Law And Rules. In The Entire Apartment Located At Apt 3r, 3rd Story, 1st Apartment From North At East , 1st Section From West At North B Violation Dismissed
06/20/14 10/22/14 Section 27-2045 Adm Code Repair Or Replace The Smoke Detector Missing In The Entire Apartment Located At Apt 3r, 3rd Story, 1st Apartment From North At East , 1st Section From West At North B Violation Dismissed

Environmental Control Board Violations (10 found)

Date Number Respondent Description Status Penalty Balance Due
2009/03/06 38201529H Pinnacle Group 17m07.42g09.98bb05.100bb05.70o02.17m 6th Fl 42g Wire Across Fuses 98bb 5yr Test 100bb 2yr Resolve $500.00 $.00
2008/01/30 38181292N The Pinnacle Group 38o02.51b07.64m07.84m07.55y10.55o02. 51b-provide Proper Anti Spin Outs84m-pit Ladder Resolve $.00 $.00
2012/09/26 38222769J Treger Management Co 70o02,81m07,100b10,69m07,42q11. 70o- Pit. 81m- Ctw Runby Sign. 100b- In Car P.i. Bulbs Out. 69m- Code Data Plate, 426 Improper Fuses Controller. Resolve $.00 $.00
2008/02/08 38181809R The Pinnacle Group 17h11.17d06.08v01.66o02.55y13.57h10.41g11.60g11. 17h Replace Where Needed 17d Loose On 6th Fl 08v Adjust Fl Stops 66o Clean Pit 55y Seal Leaks 57h Play In Worm & Gear 41,60g Illegiable Fuses Resolve $350.00 $.00
2015/05/29 38236451R Treger Management Company 40m07,40bb07,100m07. 40m-machine Room Ventilation; 40bb-fire Extinguisher; 100m-in Case Of Fire Signage In Lobby. Resolve $500.00 $.00
2008/09/25 38191132N Treger Mgmt 98bb05.99bb05.42a10.70o02.97o02. 42jumped Fuse Resolve $200.00 $.00
1998/01/14 38063940P Treger Management Co. 75m,23u,74m,50y,35o,74o,35u, 75m-perform And File For 5 Year Test 74m-07- Spin Out Cable In Cables 74-top Of Car Dirty 35u-no Nyc Tags On Devices. Resolve $.00 $.00
2015/04/29 38236037L Treger Management Company 61g11.68m07,40m07,98bb15,100m07. 61g-unreadable Fuses; 50m-ventilation Per K3; 98bb-current Tag 100m-in Case Of Fire Signage In Lobby. Resolve $500.00 $.00
2007/08/15 38168772X The Pinnacle Group 17h11-lobby & 6fl.16f-loose Door Hanger 2 & 6fl.52l-excessive Lube On Gov Rope.42n-hazard Bypass Reverse Phase Relay. Resolve $800.00 $.00
2006/10/18 38162066L The Pinnacle Group 10h11,40t7,66o2. 10h11:car Door Gibs Worn Replace Saddle, 40t7:machineroom Door Unlabeled Provide Sign, 66o2:p.t. Dirty Clean. Resolve $.00 $.00

Department of Buildings Complaints (10 found)

Date Filed Number Category Status
07/15/2013 3450403 Elevator-Danger Condition/Shaft Open/Unguarded CLOSED
01/06/2010 3329035 Failure to Maintain CLOSED
04/18/2009 3302001 Elevator-Danger Condition/Shaft Open/Unguarded CLOSED
02/16/2009 3295412 Elevator-Danger Condition/Shaft Open/Unguarded CLOSED
02/14/2009 3295321 Elevator-Danger Condition/Shaft Open/Unguarded CLOSED
08/05/2008 3275190 Elevator-Danger Condition/Shaft Open/Unguarded CLOSED
06/23/2006 3194738 Zoning – Non-conforming CLOSED
05/28/2005 3158771 Elevator-Danger Condition/Shaft Open/Unguarded CLOSED
04/14/2003 3111396 Egress – Locked/Blocked/Improper/No Secondary Means CLOSED
03/05/1996 3046214 Elevator-Danger Condition/Shaft Open/Unguarded CLOSED

311 Housing Complaints (14 found)

Date Category Type Status
08/10/20 Heat/hot Water: Entire Building Emergency The Department of Housing Preservation and Development responded to a complaint of no heat or hot water and was advised by a tenant in the building that heat and hot water had been restored. If the condition still exists, please file a new complaint.: The Department of Housing Preservation and Development responded to a complaint of no heat or hot water and was advised by a tenant in the building that heat and hot water had been restored. If the condition still exists, please file a new complaint.
06/21/20 Appliance: Refrigerator Non Emergency The Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.: The Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.
06/21/20 Unsanitary Condition: Mold Emergency The Department of Housing Preservation and Development inspected the following conditions. Violations were issued. Information about specific violations is available at www.nyc.gov/hpd.: The Department of Housing Preservation and Development inspected the following conditions. Violations were issued. Information about specific violations is available at www.nyc.gov/hpd.
06/21/20 Appliance: Electric/gas Range Emergency The Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.: The Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.
06/21/20 Appliance: Refrigerator Non Emergency The Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.: The Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.
03/24/20 Heat/hot Water: Entire Building Emergency The Department of Housing Preservation and Development responded to a complaint of no heat or hot water and was advised by a tenant in the building that heat and hot water had been restored. If the condition still exists, please file a new complaint.: The Department of Housing Preservation and Development responded to a complaint of no heat or hot water and was advised by a tenant in the building that heat and hot water had been restored. If the condition still exists, please file a new complaint.
02/03/20 Door/window: Door Frame Non Emergency The Department of Housing Preservation and Development was not able to gain access to inspect the following conditions. The complaint has been closed. If the condition still exists, please file a new complaint.: The Department of Housing Preservation and Development was not able to gain access to inspect the following conditions. The complaint has been closed. If the condition still exists, please file a new complaint.
02/03/20 Paint/plaster: Cabinet Non Emergency The Department of Housing Preservation and Development was not able to gain access to inspect the following conditions. The complaint has been closed. If the condition still exists, please file a new complaint.: The Department of Housing Preservation and Development was not able to gain access to inspect the following conditions. The complaint has been closed. If the condition still exists, please file a new complaint.
02/03/20 Flooring/stairs: Floor Emergency The Department of Housing Preservation and Development was not able to gain access to inspect the following conditions. The complaint has been closed. If the condition still exists, please file a new complaint.: The Department of Housing Preservation and Development was not able to gain access to inspect the following conditions. The complaint has been closed. If the condition still exists, please file a new complaint.
02/03/20 Flooring/stairs: Floor Emergency The Department of Housing Preservation and Development was not able to gain access to inspect the following conditions. The complaint has been closed. If the condition still exists, please file a new complaint.: The Department of Housing Preservation and Development was not able to gain access to inspect the following conditions. The complaint has been closed. If the condition still exists, please file a new complaint.
01/31/20 Unsanitary Condition: Pests Non Emergency The Department of Housing Preservation and Development inspected the following conditions. Violations were issued. Information about specific violations is available at www.nyc.gov/hpd.: The Department of Housing Preservation and Development inspected the following conditions. Violations were issued. Information about specific violations is available at www.nyc.gov/hpd.
01/11/20 Plumbing: Water Supply Emergency The Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.: The Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.
01/03/20 Unsanitary Condition: Mold Emergency The Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.: The Department of Housing Preservation and Development inspected the following conditions. No violations were issued. The complaint has been closed.
12/16/19 Heat/hot Water: Apartment Only Emergency The Department of Housing Preservation and Development contacted an occupant of the apartment and verified that the following conditions were corrected. The complaint has been closed. If the condition still exists, please file a new complaint.: The Department of Housing Preservation and Development contacted an occupant of the apartment and verified that the following conditions were corrected. The complaint has been closed. If the condition still exists, please file a new complaint.

Work Orders (6 found)

Date Created Order Type Description Charge Amount
07/30/20 Handyman apt# 6h : install/repair window guards throughout in the entire apt. remove all work related debris. $0
12/11/19 Open Market (public hall: fire stair (b) stairwell, at public hall, 2nd story) installation of self-closing door hinges @ (public hall: fire stair (b) stairwell, $165
11/06/19 Open Market at 3rd room from east at north. at west wall, fire escape window, replace with new the defective / broken counter balance at upper window sash and $275
02/20/19 Open Market window guard replacement/repair: as per requirement of h.p.d. window guard program and in accordance with the new york city health code section 24 $50
12/09/18 Handyman as per the requirement contract with hpd, provide and install 7 window guards and repair 0 window guards throughout entire apartment 2c. remove all w $38.47
08/29/18 Handyman as per requirement of h.p.d. window guard program and in accordance with the new york city health code section 24 rcny chapter 12. at entire apt#: $31.54

Office of Administrative Trials and Hearings Cases (10 found)

Violation Date Agency Respondent Charge Result Penalty Imposed Status
02/22/13 Fire Department Of Nyc Treger Management Llc Fire Protection Systems In Violation $ All Terms Met
02/22/13 Fire Department Of Nyc Treger Management Llc Fire Protection Systems In Violation $1200 All Terms Met
11/09/12 Fire Department Of Nyc Treger Management Llc Posting Of Permits And Record Keeping In Violation $ All Terms Met
05/11/12 Fire Department Of Nyc Treger Mgmt Inspection And Testing In Violation $ All Terms Met
05/11/12 Fire Department Of Nyc Treger Mgmt Inspection And Testing In Violation $ All Terms Met
03/06/09 Dept. Of Buildings Pinnacle Group Fail Maintain Bldg In Compliant Manner: Service Equipment Stipulated $500 All Terms Met
03/06/09 Dept. Of Buildings Pinnacle Group Fail Maintain Bldg In Compliant Manner: Service Equipment Stipulated $500 All Terms Met
02/08/08 Dept. Of Buildings The Pinnacle Group Failure To Maintain Elevator In Violation $350 All Terms Met
01/30/08 Dept. Of Buildings The Pinnacle Group Failure To Maintain Elevator In Violation $ All Terms Met
08/15/07 Dept. Of Buildings The Pinnacle Group Failure To Maintain Elevator - Hazardous In Violation $800 All Terms Met

Rodents (3 inspections found)

Date Result Type
09/10/19 Passed Initial
10/11/16 Passed Compliance
09/19/16 Failed For Other R Initial

Want more information on 815 Gravesend Neck Rd, Brooklyn? Click to view all records of code violations, complaints, rat inspections, evictions, vacate orders, tax liens, building permits, sales and more.


See reports on other buildings near 815 Gravesend Neck Rd, Brooklyn

Browse all buildings on this street Browse all addresses in Brooklyn


About Augrented

Augrented uses public data on apartments and landlords from the San Francisco & New York City Open Data portals and other official sources, to provide apartment and landlord ratings. Access is provided in accordance with California and/or New York State law and SF & NYC agency policies, local laws and ordinances. This service is not provided or endorsed by the DBI, HPD or any other city or government agency.

For informational purposes only. This data is not a credit report, investigative consumer report or background check, and you should not rely on it exclusively to make rental or business decisions. Please verify information with building owners or responsible agencies.