Building & Landlord Data for 1255 08Th Ave, San Francisco, CA

Renter Risk Rating
54%

54% chance of no major maintenance issues next year

High Risk Building

Apartments at 1255 08Th Ave are more likely to have maintenance issues than 72% of SF rentals.

Building Overview
Source: Assessor-Recorder
Total Apartments 6
Class Multi-Family Residential
Area 4452 sq ft
Stories 2
Owner Name Daniel & Beverly K Sue Revo
Owner Since 06/11/98

Code Violations

DBI violations
31

Complaints

311 & DBI complaints
3

Fire

Fire violations & incidents
0

Building records

Source: SF Department of Building Inspection
Date Filed Date Abated Violation Description Status
01/26/10 03/22/11 Recharge all fire extinguishers (905, 1001(m) hc) Not active
01/26/10 03/22/11 This notice includes violations for the areas noted. Common area unless otherwise noted. Not active
01/26/10 03/22/11 Permanently remove combustible storage or provide automatic fire sprinklers. (904, 1001(i) hc) Remove combustible materials from garage. Not active
01/26/10 03/22/11 Provide ventilation for garbage room (707, 1001(b)(7),(8) hc) Provide metal vent ( 16gauge ) under building permit Not active
01/26/10 03/22/11 Inspector comments It is the property owner's responsibility to be present or direct his/her representative to attend, the reinspection as scheduled on this notice of violation for the purpose of providing entry to the inspector of those areas not accessed during the initial inspection as specified, and/or to provide access to all areas cited within this notice. if the property owner cannot attend the scheduled reinspection (as specified on this notice) it is his/her responsibility to secure a different inspection date and time with the inspector, and provide all tenants with notification as required by california civil code section 1954 (san francisco housing code section 303(b), if any dwellings, apartment units or guest rooms are to be accessed during the reinspection. Not active
01/26/10 03/22/11 Asbesto covering above gas furnace 1001 hc Repair partially damaged asbesto covering above gas furnace in professional manner. This must be corrected by professional contractor. Not active
01/26/10 03/22/11 Remove egress obstruction at (801,1001(l) hc) Front passageway door: rreverse existing deadlatch. Keyhole must be on lobby side. Not active
01/26/10 03/22/11 Provide primary locking devices at exterior doors (706 hc) Rear passageway door. Not active
01/26/10 03/22/11 Provide shutoff tool for gas utility shutoff (712 hc) Not active
01/26/10 03/22/11 Sprinkler head in storage Do not block sprinkler head. Not active
01/26/10 03/22/11 Repair, maintain fire escape drop ladder in working condition (sec 908 hc) Option: 1) note: on reinspection day, property manager, owner or the owner's agent needs to demonstrate the workability of the fire escape ladders. the fire escapes are to be checked on all buildings during the course of a routine inspection. non-working fire escape ladder is a life safety hazard and must be corrected immediately or 2) note: property manager, owner or the owner's agent needs to provide a proof of the workability of the fire escape ladders. non-working fire escape ladder is a life safety hazard and must be corrected immediately. provide a written report from a qualified service company or licenced contractor stating that all parts and cables have tested and are functional or contact the housing inspector (within 30 days) to witness lowering the ladder in person. Not active
01/26/10 03/22/11 Post enclosed gas meter instructional diagram in a public area. (712 hc) Not active
03/26/02 05/02/02 Make necessary repairs to heating duct's insulation in garage area (1001 hc) **field observation** possible asbestos contained insulation at duct-pipes in garage area. many sections of insulation are separating and loose particularly at area above door leading to furnace/heater room. tape and encapsulate these area to prevent dust and further damage to the exposed materials. note: it is the responsibility of property owner / management to verify the contents of the materials and repair accordingly. Not active
03/26/02 05/02/02 Remove egress obstruction at exit hallway leading to fire escape (801,1001(l) hc) **tripping hazard** remove all stored items, bicycles and toys at the end of second floor exit hallway leading to fire escape. this area must remain clear and clean at all time. no storage allowed in emergency exit hallways. Not active
03/26/02 05/02/02 Repair central alarm system (monitoring box) (908, 909 hc) Lock central alarm system monitoring box and provide (post) current system certification. Not active
03/26/02 05/02/02 This notice includes violations for the areas noted. Routine inspection of common and public areas at 1255 08th avenue Not active
03/26/02 05/02/02 Provide shutoff tool for gas utility shutoff (712 hc) Install shut off tool in a visible and accessible location and adjacent to main gas valve Not active
03/26/02 05/02/02 Repair, maintain fire escape drop ladder in working condition (sec 908 hc) Note: property manager, owner or the owner's agent needs to provide a proof of the workability of the fire escape ladders. non-working fire escape ladder is a life safety hazard and must be corrected immediately. provide a written report from a qualified service company or contractor stating that all parts and cables have tested and are functional or contact the housing inspector (within 30 days) to witness lowering the ladder in person. **reminder** all manufacturers recommend that the fire escape drop ladder be maintained and serviced annually, particularly the cable and all moving parts. lubricate and drop the ladder at least once a year. Not active
03/26/02 05/02/02 Note for occupants information: Building code section 102.3 requires that a copy of this notice of violation be provided to each tenant or occupant of the above referenced property. if there are any questions please contact the property owner, manager, or property management company. Not active
03/26/02 05/02/02 Move garbage receptacles to area open to the sky or provide an automatic sprinkler system. (904, 906(4) hc) Note: plumbing permit will be required to install sprinkler heads above garbage cans. or relocate the cans permanently to the backyard (area open to the sky). Not active
03/26/02 05/02/02 Inspector comments regarding reinspection: I have scheduled a reinspection of your building on 04/25/2002 at 12:00 noon. reinspection of premise to include all areas referenced above. please call if you have any questions, want to reschedule or confirm the time or day of reinspection. your cooperation is appreciated. Not active
03/26/02 05/02/02 Recharge all fire extinguishers by the end of april (905, 1001(m) hc) Reminder: fire extinguishers are due for service by the end of april 2002 (reinspection day). **reminder** all fire extinguishers are required to be recharged and serviced annually and date tag must be posted and current. Not active
03/26/02 05/02/02 Permanently remove combustible storage from garage area. (904, 1001(i) hc) **fire hazard condition** remove excessive combustible storage from northwest corner of garage area. this corner is being used as a dump site for empty cardboard boxes. remove all abandoned items and keep the area clear, clean and sanitized. Not active
03/26/02 05/02/02 Post enclosed gas meter instructional diagram in a public area. (712 hc) Post diagram in a visible location so tenants are aware of emergency gas shut off procedures. Not active
01/12/00 02/22/00 Repair damaged walls and ceilings (1001b,h,o hc) At 2nd and 3rd floor public hallways and garage area. painting is required after the repair. Not active
01/12/00 02/22/00 Replace broken glass window pane (1001(h),708 hc) At 2nd floor fire exit door. Not active
01/12/00 02/22/00 Remove egress obstruction at (801,1001(l) hc) Remove debris and personal items from the fire escape. Not active
01/12/00 02/22/00 Replace deteriorated fire exit door (1001(h),708 hc) At 3rd floor. Not active
01/12/00 02/22/00 Provide smoke enclosure door closer (807,707 hc) Fire exit door leading to fire escape at 2nd & 3rd floors. Not active
01/12/00 02/22/00 Maintain the common areas - hallways, stairways, and garbage compartment, etc.. in a clean and sanitary condition at all times. sec. 1306 hc. Not active
01/12/00 02/22/00 Repair smoke enclosure door closer (807,707 hc) The garbage compartment door - ensure the door can be closed and opened in approved manner. Not active
Source: SF Department of Building Inspection
Date Filed Date Abated Division Description Status Number
01/26/10 03/22/11 Housing Inspection Services Routine, 6 units Not Active 201031964
03/26/02 05/02/02 Housing Inspection Services Routine inspection Not Active 200227102
01/12/00 02/22/00 Housing Inspection Services Apt. routine inspection. Not Active 200000696
Source: SF 311, City & County of San Francisco
Date Category Agency Type Details Status
Source: SF Department of Public Health
Date Business Name Inspection Type Violation Risk Score
Source: SF Fire Department
Violation Date Close Date Address Description Penalty Amount Status
Source: SF Fire Department
Date Primary Situation Description Disposition
Source: SF Fire Department
Complaint Date Disposition Date Description Disposition
10/04/06 Alarm Systems
Source: SF Fire Department
Inspection Date Correction Date Description Status
Source: SF Department of Building Inspection
Creation Date Cost Description Status Number
02/13/97 $6250 Reroofing Expired 9702627
Source: SF Department of Building Inspection
Creation Date Description Status Number
Source: SF Department of Building Inspection
Creation Date Type Status Number
01/25/16 Expired PMW20160125518
Source: SF Planning
Date Address Description Developer
Source: Department of Finance
Date Disclosed Date Agreed Amount Number of Tenants
Source: Assessor-Recorder
Address Units Class Code
0000 1255 08Th Av 6 Apartment 5 to 14 Units
Source: SF Department of Building Inspection
Tier Status
Source: SF Department of Building Inspection
Affidavit Date

Introducing Tenancy Protection

Don't let a bad landlord ruin your life! Our unique Tenancy Protection Plans give you peace of mind–and legal help with your landlord if you ever need it, including Eviction Defense coverage.

Read on and rent safer

Need tips on how to find and keep the best apartments, avoid bad landlords and more? Check out our blog for tips every tenant needs!

How Augrented Works

How do you predict what's going to happen at a building? Can landlords pay to change their rating? Answers to these and many more questions here!

Lease fraud: 10 things to look out for

Did you know almost all apartment leases contain at least one unenforceable or misleading clause? Here are some common signs your landlord isn't playing fair.

How to save time apartment hunting

Especially in these risky times, everyone wants to avoid wasted trips to view over-sold apartments. We've put together a guide to screening before even viewing.